Switchboard measuring static transducers
|
|||||||
With galvanic insulation |
|||||||
mod. CPA-1 |
Active Power SINGLE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPA-3 |
Active Power balanced 3 wires THREE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPA-4 |
Active Power balanced 4 wires THREE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPA-6 |
Active Power unbalanced 3 wires THREE-PHASE circuit ( ARON ) |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPA-8 |
Active Power unbalanced 4 wires THREE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
Without galvanic insulation |
|||||||
mod. CW-1 |
Active Power SINGLE-PHASE circuit Without insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CW-3 |
Active Power balanced 3 wires THREE-PHASE circuit Without insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CW-4 |
Active Power balanced 4 wires THREE-PHASE circuit Without insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CW-6 |
Active Power unbalanced 3 wires THREE-PHASE circuit ( ARON ) Without insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CW-8 |
Active Power unbalanced 4 wires THREE-PHASE circuit Without insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
Frequency transducers |
Back to "Switchboard transducers" |
Reactive Power transducers |
|