Switchboard measuring static transducers
|
|||||||
With galvanic insulation |
|||||||
mod. CPR-1 |
Reactive Power SINGLE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPR-3 |
Reactive Power balanced 3 wires THREE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPR-4 |
Reactive Power balanced 4 wires THREE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPR-6 |
Reactive Power unbalanced 3 wires THREE-PHASE circuit ( ARON ) |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CPR-8 |
Reactive Power unbalanced 4 wires THREE-PHASE circuit |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
Without galvanic insulation |
|||||||
mod. CV-1 |
Reactive Power SINGLE-PHASE circuit Without galvanic insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CV-3 |
Reactive Power balanced 3 wires THREE-PHASE circuit Without galvanic insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CV-4 |
Reactive Power balanced 4 wires THREE-PHASE circuit Without galvanic insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CV-6 |
Reactive Power unbalanced 3 wires THREE-PHASE circuit ( ARON ) Without galvanic insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
mod. CV-8 |
Reactive Power unbalanced 4 wires THREE-PHASE circuit Without galvanic insulation |
||||||
|
GENERAL FEATURES Overall dimensions: 110 x 144 x 85 mm Housing: Self-extinguish material Accuracy: 1% standard , 0.5% on request Working temperature: 0 - 50°C Insulation between: inputs - output : 2 kV / 1 min at 50 Hz inputs - aux. supply : 2 kV / 1 min at 50 Hz Test voltage: 4 kV / 1 min at 50 Hz Reference standards: according to IEC, publ. 348, VDE0411, DIN 40050 Load-independent direct current |
||||||
Active Power transducers |