Logo FASE FASE
Strumenti elettrici di misura
Low-Voltage Potential Transformers


mod. TV-3

mod. TV-3

GENERAL FEATURES

Overall dimensions:
   54 x 62 x 46 mm
Frequency:
   50 - 60 Hz
Rated secondary voltage:
   100 V
Rated voltage factor:
   1.2 continuous
Highest system voltage:
   0.72 kV up to 600V
   1.44 kV up to 1000V
One minute test voltage
between primary and secondary
:
   3kV up to 600V, 6kV up to 1000V
Primary
voltage
( V )
Burden (VA)
Accuracy
0.5 1 3
100
110
220
380
400
500
500
600
800










3
3
3
3
3
3
3
3
3



mod. TV-6

mod. TV-6

GENERAL FEATURES

Overall dimensions:
   84 x 69 x 91 mm
Frequency:
   50 - 60 Hz
Rated secondary voltage:
   100 V
Rated voltage factor:
   1.2 continuous
Highest system voltage:
   0.72 kV up to 600V
   1.44 kV up to 1000V
One minute test voltage
between primary and secondary
:
   3kV up to 600V, 6kV up to 1000V
Primary
voltage
( V )
Burden (VA)
Accuracy
0.5 1 3
100
110
220
380
400
500
500
600
800
1000
1500





6
6
6
6
6
6
6
6
6
6
6








mod. TV-10

mod. TV-10

GENERAL FEATURES

Overall dimensions:
   97 x 78 x 100 mm
Frequency:
   50 - 60 Hz
Rated secondary voltage:
   100 V
Rated voltage factor:
   1.2 continuous
Highest system voltage:
   0.72 kV up to 600V
   1.44 kV up to 1000V
One minute test voltage
between primary and secondary
:
   3kV up to 600V, 6kV up to 1000V
Primary
voltage
( V )
Burden (VA)
Accuracy
0.5 1 3
100
110
220
380
400
500
500
600
800
1000
1500





10
10
10
10
10
10
10
10
10
10
10








mod. TV-30

mod. TV-30

GENERAL FEATURES

Overall dimensions:
   121 x 83 x 119 mm
Frequency:
   50 - 60 Hz
Rated secondary voltage:
   100 V
Rated voltage factor:
   1.2 continuous
Highest system voltage:
   0.72 kV up to 600V
   1.44 kV up to 1000V
One minute test voltage
between primary and secondary
:
   3kV up to 600V, 6kV up to 1000V
Primary
voltage
( V )
Burden (VA)
Accuracy
0.5 1 3
100
110
220
380
400
500
500
600
800
1000
1500





30
30
30
30
30
30
30
30
30
30
30






Voltage Transformers on metallic case

mod. TVN-10

mod. TVN-10

GENERAL FEATURES

Overall dimensions:
   165 x 105 x 123 mm
Frequency:
   50 - 60 Hz
Rated secondary voltage:
   100 V
Rated voltage factor:
   1.2 continuous
Highest system voltage:
   0.72 kV up to 600V
   1.44 kV up to 1000V
One minute test voltage
between primary and secondary
:
   3kV up to 600V, 6kV up to 1000V
Primary
voltage
( V )
Burden (VA)
Accuracy
0.5 1 3
100
110
220
380
400
500
500
600
800
1000
1500
5
5
5
5
5
5
5
5
5
5
5
10
10
10
10
10
10
10
10
10
10
10








mod. TVN-20

mod. TVN-10

GENERAL FEATURES

Overall dimensions:
   175 x 105 x 123 mm
Frequency:
   50 - 60 Hz
Rated secondary voltage:
   100 V
Rated voltage factor:
   1.2 continuous
Highest system voltage:
   0.72 kV up to 600V
   1.44 kV up to 1000V
One minute test voltage
between primary and secondary
:
   3kV up to 600V, 6kV up to 1000V
Primary
voltage
( V )
Burden (VA)
Accuracy
0.5 1 3
100
110
220
380
400
500
500
600
800
1000
1500
10
10
10
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
20
20
20
20








Previous
TAD series

 
Back to
"Accessories for AC meters"
Next
Custom

FASE - Via del Lavoro, 41 - 20030 Senago (Milano) - Italy
Tel. +39 029986557 - Fax +39 029986425

[Home][Profile][Products][E-Mail]